精品亚洲aⅴ无码一区二区三区,日本一卡二卡3卡四卡网站精品,丰满熟妇乱又伦精品,性一交一乱一伦一色一情孩交,亚洲无亚洲人成网站9999,亚洲欧洲日产国码高潮αv,欧美精品偷自拍另类在线观看,又大又粗欧美成人网站
Location: Home >>Product >>Fault Location

Distributed fault location device for transmission lines

型號:DX-WPS100-GZ01

Online Inquiry+8618926454155


Product details

Distributed fault location and hidden danger monitoring device for transmission lines

model:DX-WPS100-GZ01

1、 Demand analysis

With the increasing number of high-voltage long-distance overhead transmission lines, transmission lines, as the link of energy transmission, are the basis for the safe and stable operation of the whole system; Once a fault occurs on the transmission line, it is necessary to find the fault point as soon as possible, eliminate the fault and restore power supply. However, as high-voltage and ultra-high voltage transmission lines are often exposed to different environments and distributed in a wide geographical area, the operating environment is harsh; Therefore, it is also a place where many faults occur in the power system. It is very important to quickly and accurately find the fault point after the line fault, not only for timely repair of the line and rapid restoration of power supply, but also for the security, stability and economic operation of the entire power system.


2、 Working principle

The distributed fault location and hidden danger monitoring device for transmission lines adopts the distributed traveling wave measurement technology. The monitoring terminals are distributed on the transmission line conductors. The power frequency fault signals and traveling wave fault signals near the line fault time point are collected at high potential and sent back to the background data center in 4G/5G wireless ways. Through the comprehensive analysis of the data center, the fault point can be quickly and accurately determined according to different fault characteristics, Improve fault location accuracy to improve fault line patrol efficiency, and also capture transient fault traveling wave waveform to intelligently identify whether the fault is a lightning strike fault or a non lightning strike fault, and whether the lightning strike fault is a shielding strike or a counterattack. The diagnosis results are displayed in two ways: web and SMS, and sent to users, which is helpful to timely repair the fault line and ensure the safe and stable operation of the whole power grid.


3、 Product Functions

(1) Basic configuration of fault location monitoring: main control unit, fault location monitoring unit, communication unit, inductive power supply unit, solar power supply unit, mounting bracket and auxiliary materials.

(2) Detection and calculation of fault distance: it can accurately detect and record the distance of single-phase ground fault, interphase short circuit fault, open circuit fault and instantaneous fault of the line online;

(3) High precision fault location: it can accurately determine the fault section of transmission line, and the reliability of section location is more than 99%;

(4) The error is not more than 300 meters: it can accurately determine the fault location of the transmission line, and the location error is 300 meters

(5) Fault cause identification function: it can identify lightning strike fault and non lightning strike fault, and the accuracy of lightning strike and non lightning strike fault identification is more than 95%;

(6) High identification accuracy: it can identify shielding failure and counterattack failure, and the identification accuracy of lightning strike fault nature is more than 90%

(7) Dual RAM recording technology: dual RAM recording technology is adopted to eliminate the "dead zone of recording" of transient signals and prevent the omission of fault data caused by lightning current interference;

(8) It can record line lightning current, locate lightning strike points and count lightning strike times online;

(9) It can detect line load current online, including timing return and call to measure load current data;

(10) The software has the functions of automatic fault identification, output alarm and data file storage;

(11) 4G/5G wireless transmission: 4G/5G network encryption transmission, measurement;

(12) Support remote upgrade: support remote parameter setting and program upgrade


4、 Technical parameters

Serial No

category

project

technical parameter

1     

Overall performance

Complete machine configuration

Main control unit, fault location monitoring unit, communication unit, inductive power supply unit, solar power supply unit and installation auxiliary materials.

2     

Overall quality

Less than 15KG

3     

texture of material

Aluminum mold body

4     

Fault location monitoring unit

Fault location sensor

Interval positioning reliability ≥ 99%; Positioning error ≤ 100m

5     

Detect line length

30km

6     

Traveling wave sensor broadband

1kHz2MHz

7     

Traveling wave sampling rate

5MHz

8     

Single conductor fault current measurement range

10A15000A(Valid value)

9     

Continuous recording duration of traveling wave current

1000μs

10    

Communication unit

communication mode

All Netcom 4G/5G/WIFI wireless transmission

11    

Data security

VPN dedicated channel can be used for communication with the master station, and encryption transmission is optional.

12    

Access protocol

Access to monitoring platforms of provincial power companies such as Southern Power Grid and State Grid

13    

Power supply unit

Power supply mode

The normal working current range of induction power supply and solar power supply is 30~1000A;

14       

Power supply duration

The power supply requirement that the device can operate normally for 30 days without continuous illumination.

15       

Other parameters

work environment

Working temperature: - 40~+70 ℃; Relative humidity: 5-99% RH

16    

Overall service life

More than 8 years

17    

Degree of protection

IP67




Contact us

Shenzhen Dinsee Smart Technology Co.,Ltd
Tel:0755-21612345?Mobile&Whatsapp:+8618926454155
Fax:0755-21612345Whatsapp:+8618926454155E-Mail:business@szdx.com
Address: Building 2,xiangyuer Industry Part,NO.8 Longsheng Road,Longgang District,Shenzhen 518126,China

The online monitoring, distributed fault location and cable online monitoring equipment for power transmission and distribution lines launched by SHENZHEN DINSEE SMART TECHNOLOGY CO.,LTD. has been widely used in Southern Power Grid and State Grid, and has achieved good results.

Record No.: Yue ICP Bei 2022070794-1 | Website Map XML Map

主站蜘蛛池模板: 伊人久久大香线焦av综合影院| 伊人久久大香线蕉影院| 亚洲成aⅴ人在线视频| 日韩精品无码中文字幕电影| 国产精品无码久久久久久久久久| 99热国产这里只有精品9| 国产自偷亚洲精品页65页| 日本午夜精品一区二区三区电影 | 东京热人妻无码一区二区av| 欧美制服丝袜人妻另类| 国产av亚洲精品久久久久久小说| 精品熟女少妇av久久免费软件 | 欧洲人激情毛片无码视频| 92国产精品午夜福利无毒不卡| 国产色产综合色产在线视频| 黑人巨大无码中文字幕无码| 97人妻碰碰视频免费上线| 国内高清久久久久久| 青青草国产成人久久电影| 久久综合色另类小说| 国产夫妇肉麻对白| 成人看片黄a免费看那个网址| 97精品伊人久久久大香线蕉| 午夜无码福利伦利理免| 精品 在线 视频 亚洲| 免费无码一区无码东京热| 五月丁香综合缴情六月小说| 亚洲中文字幕va福利| 亚洲国产欧美日韩精品一区二区三区| 97热久久免费频精品99| 日本大片免a费观看视频三区| 成人午夜亚洲精品无码区毛片| 国产精品免费_区二区三区观看| 深夜福利av无码一区二区| 亚洲综合熟女久久久40p| 欧美人与牲动交xxxx| 亚洲啪啪综合av一区| 中文字幕久久精品一二三区| 国产剧情福利av一区二区| 18禁无遮挡羞羞污污污污免费| 小说区亚洲综合第1页|